Standalone data logger ---- SDL-1 (Item No.
#B01)
SDL-1
The logger is initialised by a
Window 95/98 compatible software via the serial port of a personal computer
or a portable computer. Once it is initialised, the logger can be
disconnected from the PC and deployed to the designated locations. The
logger will only measure voltage, therefore, a suitable sensor is need in
the end application.
After the logger enters a
logging session, the SDL-1 can be programmed to sleep for a pre-set period
of time before the 1st measurement is taken. After this, it will
automatically measure voltage and store that in the on-board memory at the
preset interval. Two logging modes are available: continuous mode and
intermittent mode. In the first mode, the logger will capture data at a
regular interval. In the latter, the logger will capture data, then stop.
After a preset period of time, data logging will start again.
|
-
9-pin female D-type RS232
connector
-
Initialisation and data
download via RS232 port of PCs. Windows 95/98 driver for initialisation
and download
-
Download data file format: DOS
delimited text format ready for spreadsheet applications
-
1 mV accuracy. Voltage input range: 0-4.096 V
-
Excitation voltage output: 5V
at 50mA
-
On-board data storage
capacity: 4096 data points
-
Two logging modes: continuous
and intermittent (cycle period: 1 minute to 2 hours in 1 minute step).
-
Programmable logging rate at1,
5, 10 and 20 Hz
-
Programmable sleep time before
logging
-
Connection to the logger
through an 8-pin mini DIN female socket
-
Slim size: 100mm by 60mm by 25
mm.
-
Current consumption during
sleep: 0.8 mA.. Current consumption during logging: 4 mA. (note: no drain
on the excitation output)
-
Use a PP3 9V battery
- Operation temperature
range: 0 to 70 deg C
After the data logging session
is completed, the logger is re-connected to a computer and temperature data
stored in the logger are downloaded into a PC and saved as a DOS text file.
The file can be import into spreadsheet programs such as Lotus 123 and
Microsoft Excel for further analysis.
Datasheets |
|
Price |
Item Name: SDL-1
Item Number: #B01
Price: £86.00
|
Standalone temperature logger---- T-LOGGER (Item No.
#B02)

T-LOGGER
is a low-cost standalone temperature logger.
Working on its own, the logger can measure temperature and store the value into its
on-board memory for future retrieval.
 |
It is
initialised by a Window 95/98 compatible software via the serial port of a personal
computer or a portable computer. Once it is initialised, the logger can be disconnected
from the PC and deployed to the designated locations. The logger will then automatically
measure temperature and store that in the on-board memory at the preset interval. After
the data logging session is completed, the logger is re-connected to a computer and
temperature data stored in the logger are downloaded in a PC.
-
Initialisation
and download via RS232 port
-
9-pin
D-type female connector for RS232 port
-
Measurement
resolution: 0.5 deg C, +/- 2 deg C before calibration, +/- 0.5 deg after calibration
-
Allow
user on-site calibration
-
Selectable
scanning interval (1-255 minutes scan interval)
-
Selectable
start mode (manual and auto)
-
Selectable
delay period (from 1 minutes to 48 hours)
-
Temperature
stored as a function of time (up to 2048 data points)
-
Temperature
stored as histogram (63 bins from -40 to 85 deg C, 2 deg resolution)
-
Slim
size: 70mm by 70mm by 27 mm. Vented casing
-
Use
one 3V lithium button cell for 5 years operation
-
Windows
95/98 driver
-
Operation
temperature: -10 to 85 deg C
Datasheets |
|
Price |
Item Name: T-Logger
Item Number: #B02
Price: £39.00 |
Voltage & temperature recorder---- X-LOGGER (Item No. #B03)
|

X-LOGGER is a standalone voltage and temperature logger.
It can meausre up to 3 voltages channels and one temperature channel. Working on its own,
the logger can measure V and T and store the values into its on-board memory for future
retrieval.

|
It is
initialised by a Window 95/98 compatible software via the serial port of a personal
computer or a portable computer. Once it is initialised, the logger can be disconnected
from the PC and deployed to the designated locations. The logger will then automatically
measure temperature and store that in the on-board memory at the preset interval. After
the data logging session is completed, the logger is re-connected to a computer and
temperature data stored in the logger are downloaded in a PC.
-
Initialisation
and data download via PC via 9-pin D-type female connector for RS232 port
-
1
temperature measurement channel and 0.5 deg C for temperature and three 0.007969V for
voltage channels
-
Accuracy:
+/- 2 deg C for temperature and 0.3% for voltage measurements before calibration
-
Available
channel combinations: one voltage channel only, two voltage channels, one voltage and one
temperature channel and 2 voltages and 1 temperature channel.
-
Data
memory size: 2048 (for one channel) 512 (for 4 channels)
-
Selectable
sampling rate (in 1 minute step)
-
1st
voltage and channel and temperature stored as a function of time or as stored as a
histogram
-
Ultra
small size
-
Use
one 3V lithium button (1620) cell for 10 years operation
-
Windows
95/98 driver
-
70mm x
70mm x 27mm
Datasheets |
|
Price |
Item Name: X-Logger
Item Number: #B03
Price: £66.00 |
6-ch data recorder module ---- JET LOGGER (Item No.
#B04)

(supplied in board version only)
Jet-logger is a
standalone 6-channel logger. Working on its own, the logger can measure
voltages and store the data into its on-board memory for future retrieval.
Various modern sensors available in the market can be connected to the
logger. Connected to the Serial port of a computer, the logger can be also
used as an o-line data logger.


Jet Logger is used in
a temperature logger |
The logger is initialised by a Window
95/98 compatible software via the Serial port of a personal computer or a
portable computer. Once it is initialised, the logger can be disconnected
from the PC and deployed to the designated locations. The logger will wake
up after a programmed delay and log data. The data logger can be also used
as an on-line data logger.
After the data logging session is completed, the
logger is retrieved and connected to a computer. Data stored in the logger
is downloaded in a PC and saved into a DOS text file. The file can be read
into spreadsheet programs such as Lotus 123, Microsoft Excel for further
analysis.
The JET LOGGER is supplied in OEM version (PCB
version). It can be implemented in users’ circuits, adding standalone data
logging functions. Various sensors can be used with the JET LOGGER.
- Cost-effective and versatile standalone
data logging solution
- OEM version, (65mm by 57mm by 20 mm), can
be implemented into users’ circuits easily
- Initialisation and download via RS232 port
- Data file format: DOS delimited text format
ready for spreadsheet applications
- Windows 95/98 driver
- 6 analogue inputs, 0-2.5V input range,
single ended
- Resolution: 0.6 mV (12 bits)
- Accuracy (over 0-35deg C): +/- 1 mV
- Controlled excitation voltage to sensors
(+5V max 100mA)
- Programmable sleep time period
- Selectable scanning rate (number of minutes
between two temperature measurements: 0.5 second, 1 second to 60 seconds
in 1 second step. 1 minute to 255 minutes range)
- Highly accurate and temperature compensated
real-time clock
- 8 Kbyte (8192 bytes) on-board memory.
Number of scans (6 channels per scan) is 890.
- Power supply: 5.5V to 8V
- Current consumption: 4 mV in active mode
and 2 mV in idle mode
- During a logging session, operation of the
logger can be monitored by a computer without affecting its current
operation
- Can be also used as a RS232 on-line data
logger (6 channels)
- Extensive hardware diagnostics for
effective health checking during system integration development
- On-line data logging facility provided.
Users can issue a command through the RS232 port and receive data from the
data logger. A programming example is provided to show how this is done.
- Operation temperature range: -10 to 85 deg
C
Datasheets |
|
Price |
Item Name: Jet Logger
Item Number: #B04
Phone for price |
Standalone 1-ch data logger module (Item No.
#B05)

(supplied in board version only) |
- Built around PIC16C84 microcontrollers
- Initialised by a PC via RS232 port
- Data downloading to a PC after a data logging session
- 1 analogue input channel, 0-2.5V input
range, 12 bit
- Accuracy of on-board voltage reference: 1%
- Programmable initial sleep period
- Scanning rate: 1 second, 1 minute and 1
hour (selectable)
- Maximum number of scans stored: 1000 data
points (each 12-bit)
- Housed in a smart-looking box with a
compartment for a PP3 9V battery
- DOS TP6 source code and EXE files, PIC
assembler source code and HEX codes
Using suitable sensors to measure various
physical parameters such as temperature, humidity, light intensity, magnetic
field, sound level, etc. |
|
Price |
Item Name: 1-ch logger module
Item Number: #B05
Price: £50.00 |
Standalone event logger module (Item No. #B06)

(supplied in board version) |
- Built around PIC16C84 microcontroller
- Initialised by a PC via RS232 port
- Data downloading to a PC after a data
logging session
- Record time stamps of events: year, month,
day, hour, minute and second.
- Maximum event logging rate: 2
samples/second
- Maximum events to be recorded: 1000 events
- Event sensor could be a simple on-off
switch (such as a reed switch). It also accepts digital signals (no event
sensors are supplied with the logger)
- Housed in a smart-looking box with a
compartment for a PP3 9V battery
- DOS TP6 source code and EXE files, PIC
assembler source code and HEX code
|
|
Price |
Item Name: 1-ch event logger module
Item Number: #B06
Price: £50.00 |
|